BSEE, EIT · Staff Systems Integration, Release & Production Systems Engineer · U.S. Citizen · Kent, WA / Remote

Barton Schaefer

Electrical Engineer who treats software, firmware, and hardware as one integrated toolkit—building, securing, troubleshooting, and shipping production systems end-to-end. Available for Contract (1099/C2C/W-2) and Staff IC engagements.

Core Engineering Lanes

Digital Systems & M2M Communications

End-to-end physical-to-application systems across 8/16/32-bit MCUs/DSPs (ARM/STM32, TI, Microchip), serial/fieldbus & wireless modules (UART/RS-485, USB/VCP, CAN, SPI, I2C, HSSB; Nordic/Renesas BLE), and EMI/signal troubleshooting.

Production Test, Calibration & Compliance

Flow-loop & environmental-sensor calibration, electronic registration, ATC & totalizer verification, factory batch testers, vibration test-to-failure, Kaizen cell restructuring, and Class I Div 1/2 & 21 CFR Part 11 readiness.

Security, Persistence & Release Engineering

Hybrid symmetric/asymmetric cryptography (X.509, encrypted firmware containers, tamper-evident data sealing), power-loss-safe settings persistence, stateless CI/CD signing tooling, and multi-MCU bootloader orchestration.

Technical Case Studies

1. ST (STM32) Reference Secure Boot & 1 kHz Diagnostic Suite (Onicon)

  • Problem: Commercial flow and BTU meter families required unified field/factory commissioning, real-time telemetry, and protected firmware updates without maintaining separate tools or embedding signing secrets in CI repos.
  • Architecture: Built a unified desktop diagnostic suite with a 1 kHz real-time telemetry display, verified backup/secure-flash/restore workflows, and an external metadata-driven attribute database (onboarding new meter lines without recompilation); specified a custom encrypted firmware container and stateless runtime-injected signing CLI.
  • Verification & Outcome: Deployed onto shop-floor production PCs; built the ST (STM32) reference signing/updater implementation (timed bootloader capture handshake, hardware gating, pre-commit integrity), subsequently applied by the firmware team across ONICON’s product families.

2. Regulated Data Sealing & $3k–$5k Sensor Line Rehabilitation (Seametrics)

  • Problem: Legacy C++ water-metering software and a high-margin acquired environmental sensor line suffered from 3-year-old abandoned build tools, calibration defects, and no in-house firmware update path.
  • Architecture: Replaced legacy C++ metering software with a unified desktop suite featuring worldwide region-regulated data formatting and hybrid symmetric/asymmetric cryptographic report sealing; reconstructed legacy installers and partnered with hardware/firmware leads to add on-the-fly firmware upgrade/downgrade by sensor configuration.
  • Verification & Outcome: Resolved calibration-accuracy defects on $3k–$5k sensors (nominated by production floor for Quality, Innovation & Partnership), delivered a time-motion ROI study paying back a $4K calibration-station upgrade in 2 weeks, and contributed across 50%+ of site-wide Kaizen events (7+ events).

3. Class I, Div 1/2 Custody-Transfer Registers & Sub-Zero EMI Isolation (MID:COM)

  • Problem: Custody-transfer fuel registers required unified multi-MCU hazardous-location certification across Class I Div 2 and intrinsically safe Class I Div 1 hardware, integration across 100+ OEMs, and field reliability on commercial aircraft refuelers at −35°C.
  • Architecture: Engineered unified multi-MCU firmware, centralized UART/USB settings cloning suites, host software supporting hundreds of legacy I/O formats, and a versioned, linted, rollback-capable release pipeline across ~30 MCU products; coordinated NIST, W&M, UL, CE, Intertek, and ETL compliance.
  • Verification & Outcome: Supported 100+ active OEM/integrator dev systems (including Veeder-Root), ran vibration-table test-to-failure hardware qualification, and remotely isolated high-frequency EMI on 4–20 mA analog control loops at −35°C.

Experience & Live Shipped References

Rainier Integration Systems · Independent Systems Integration Engineer 2024 – Present · Kent, WA

Independent contract (1099/C2C/W-2) practice focused on M2M device-to-host interfaces, provisioning & settings-persistence suites, factory test/calibration tooling, and host/multi-MCU release engineering—alongside active ARM/STM32 hardware-security bring-up, motor/sensor control loops, and automated verification harnesses.

Seametrics · Senior Software Engineer 2023 – 2024 · Kent, WA (Internal Transfer from Onicon)

Replaced legacy C++ metering software with a unified desktop suite featuring worldwide regulatory formatting and hybrid cryptographic report sealing; rehabilitated calibration, installers, and automated firmware configuration for $3k–$5k environmental sensors; built factory opto-isolator batch testers and SQL Server serial-number persistence; contributed across 50%+ of site-wide Kaizen events (7+ events) supporting two new production lines and an expanded flow loop.

Onicon · Senior Software Engineer 2019 – 2023 · Tampa, FL (Remote)

Architected the unified desktop commissioning, calibration, and USB-to-Serial diagnostic suite (1 kHz real-time telemetry display, verified backup/secure-flash/restore, metadata-driven attribute database; deployed onto shop-floor production PCs); specified a custom encrypted firmware container and built the ST (STM32) reference signing/updater implementation and stateless CI/CD signing CLI applied across ONICON’s product families.

Midwest Computer Register (MID:COM) · Staff Engineer 2005 – 2016 · Hampton, IA

Primary multi-MCU embedded firmware engineer (unified firmware across Class I Div 2 and intrinsically safe Class I Div 1 custody-transfer hardware) and solo host-software engineer; managed NIST/UL/CE compliance, ATC & totalizer verification, 100+ active OEM/integrator dev systems (including Veeder-Root), national trade shows, and vibration-table test-to-failure qualification.

Suburban Software Systems · Staff Engineer 2002 – 2005 (Intern 1996 – 1998) · Bessemer, AL

Engineered the industry’s first in-cab UART fuel-register integration platform (Cover of BPN Magazine) across five register vendors plus internal operations tooling for sister company Suburban Equipment; architected a desktop/mobile fleet mapping, geofencing, routing optimization, and OBD-II telemetry suite on PC-native mapping.

CimWorks / GE Fanuc · Software Engineer / Project Manager 1998 – 2002 · Kirkland, WA

Technical PM on a 60-page automotive OEM RFQ for portable SPC metrology hardware; engineered an NDA-covered FANUC 20 Mbps HSSB deterministic G-code deployment interface (live at IMTS Chicago, followed by ongoing trade-show technical leadership); project-managed a 21 CFR Part 11 compliance retrofit (SQL Server & Oracle); GE Six Sigma Green Belt.